Speed controller aRo
Transformer-based speed controllers are used to control the rotational speed of single-phase electric motors only, in which it is possible to regulate the speed by changing the voltage. Multiple devices can be connected to one controller as long as their total load does not exceed the controller’s maximum capacity.
Choosing a controller for our industrial fans
Models and technical specification
Connection
Documents
Choosing a controller for our industrial fans
Transformer-based regulators can operate in a system, not just on a single device. The selection of the best option for a specific installation should be made by an experienced electrician or installer who can calculate the total load that the regulator will be subjected to. The device should not be too large or too small for the system it controls. An improperly chosen regulator will not only be uneconomical but also inconvenient for everyday use. In the case of choosing an aRo with too low nominal current, it will turn out that the resistance it applies is too small to affect the controlled installation. An oversized regulator will not render the device unusable, but it will only reduce the range of adjustment, which may be so small that the user will not be able to intuitively control it. We ask for caution and the use of professionals’ experience in electrical systems, as improper connections can be very dangerous for devices. A table of suggested regulators for individual airRoxy industrial fans is available.
model | aRok | aRos | aRw | aRk | aRd | aRil |
---|---|---|---|---|---|---|
aRo 100 | 200 250 300 350 400 | 200 250 300 350 400 | 150 160 200 250 315 350 | 160 | 100 125 150 160 200 250 | 100 125 150 160 200 |
aRo 400 | 450 500 550 630 710 800 | 450 500 550 630 710 800 | 350 | – | 250 315 | 250 310 |
Models and technical specification
model | code | max current | voltage frequency | fuse | net weight | IPX | pcs in package |
---|---|---|---|---|---|---|---|
100 | 01-290 | 0.1 – 1.0 A | 230V/50 Hz | F1.25 A-H | 0.36 | IP44/IP54 | 10 |
400 | 01-291 | 0.4 – 4.0 A | 230V/50 Hz | F5.0 A-H | 0.36 | IP44/IP54 | 10 |
[mm] | aRo 100 | aRo 400 |
---|---|---|
A | 23 | 23 |
B | 32 | 32 |
C | 52 | 52 |
G | 60 | 60 |
L | 82 | 82 |
Connection
Documents